Language
Search
Product News
Upcoming Events
- Building material characterization by X-ray methods
Mar 11, Complimentary webinar - Cast Expo
Mar 20-23, Orlando, Florida, USA - IM20
Mar 21-24, Miami, Florida, USA - Analytica
March 23-26, Munich, Germany - BCA
April 12-15, Warwick, Great Britain - Control 2010
May 04-07, Stuttgart, Germany
![]() |
Special Offers
The following used systems and components are for sale. These items have to be refurbished before resale, therefore the delivery time will probably be 2 months. If you have any questions, please contact our service persons:
Klaus Bohländer (Germany, Austria, Switzerland):
Tel. +49 721 595 6289
E-mail: klaus.bohlaender@bruker-axs.de
Werner Griessmeier (all other countries):
Tel: +49 721 595 6429
E-mail: werner.griessmeier@bruker-axs.de
Systems
| S4 PIONEER | Location: Karlsruhe |
| Age: about 5 years | |
| Specification: | |
| - SN 202793, ex SAP 602766 | |
| Configuration: | |
| S4P | |
| S4 with He | |
| 60 pos. PW | |
| 10 Sample Cups 34 mm Steel | |
| SC, FC | |
| Crystals LiF200, Ge, PET, XS55, XS-C | |
| Collimators: 0,23°, 0,46°, 1° | |
| Tube AG 66 used ca. 1 year old | |
| Remark: | |
| - Warranty period 6 months | |
| - Shipment terms EXW Karlsruhe acc. to Incoterms 2000 | |
| - For more information, please contact the above mentioned service persons. | |
| D4 ENDEAVOR | Location: Karlsruhe |
| Age: about 2 years | |
| Specification: | |
| - Config.: D4-2A2A1-A1 with Szintation Counter, Variable Slits, sec. Monochromator | |
| - PC + Printer | |
| Additional: | |
| VANTEC-1 to this D4 | |
| Remark: | |
| - Price without installation | |
| - ex Works Karlsruhe | |
| - Delivery 6-8 weeks | |
| - Warranty 1 year | |
| - For more information and prices, please contact the above mentioned service persons. | |
| - Price on application |
Components
| WATER-TO-AIR REFRIGERATED HEAT EXCHANGER, SINGLE PUMP |
| Age: 7 years |
| R100 Mechanically refrigerated heat exchanger uses low-pressure refrigerant. Heat removal capacity 3,150 Watts with 80 F cooling air. |
| Includes option ABOR: |
| - flowmeter, high-temperature thermostat to shut off pump |
| - manual shut-off valves |
| - and high-capacity pump. |
| Remark: |
| - Not used before! |
| - No warranty |
| - Price on request |
| - For more information, please contact the above mentioned service persons. |
| MONTEL200 MULTILAYER OPTICS FOR 2ND PORT OF MICROSTAR RA X-RAY GENERATOR |
| Part No: 592465 |
| High Brilliance Multilayer Optics with complete alignment hardware featuring: |
| - Unequalled brilliance, with very high monochromaticity |
| - Secondary focusing distance of 380 mm |
| - Complete hardware integration and interface for direct coupling of mirrors to X-ray tube providing maximal stability |
| - Easy and simple alignment by using two orthogonal micrometer translations and two orthogonal micrometer rotations |
| - Supplied with vacuum pump enabling operation in vacuum. |
| Remark: |
| - For more information, warranty, and prices, please contact the above mentioned service persons. |
| HELIOS Cu X-RAY OPTICS FOR MICROSTAR OR FR591 | Location: Karlsruhe |
| Part No: 591468 | |
| High Brightness Multilayer Optics for use on X8 PROTEUM/FR591or MicroSTAR with Copper (K-alpha) radiation with complete alignment hardware featuring: | |
| - Unequalled brilliance, with very high monochromaticity | |
| - Secondary focusing distance of 300 mm | |
| - Complete hardware integration and interface for bayonet coupling of mirrors to RA port providing maximal stability | |
| - Easy and simple alignment by using two orthogonal micrometer translations and two orthogonal micrometer rotations | |
| - Supplied with vacuum pump enabling operation in vacuum 50/60Hz and 230/110V | |
| - X-ray safety assurance system | |
| - Divergency limitations for use with X8 PROTEUM. | |
| Remark: | |
| - Warranty on application | |
| - For more information and prices, please contact the above mentioned service persons. | |
| - Price on application |
| WATER CHILLER | Location: Karlsruhe |
| Age: about 2,5 years | |
| External closed cooling-water circuit for cooling of Turbo X-ray source generator and tower. The waste heat is exhausted into the air, therefore an external installation is recommended. | |
| Technical data: | |
| - Cooling capacity: 20 kW at ambient temperatures of up to 32°C | |
| - Water reservoir: 200 l | |
| - Water conditions cooling circuit: | |
| - temperature: 18°C | |
| - flow: 20 l/min at 3.5 bar | |
| - Automatic safety switch off at excessive temperature and excess pressure | |
| - Dimensions: 855 x 1360 x 1752 mm, w x d x h, another 0.5 m space required in each direction for a proper installation. | |
| - Weight: 470 kg | |
| Requirements: | |
| - Mains supply voltage: 400 V / 3 phases / 50 Hz | |
| - Cooling water for the reservoir needs to be of be-distilled quality | |
| Remark: | |
| - Type ERL K140A1 | |
| - Warranty 6 months | |
| - For more information and prices, please contact the above mentioned service persons. | |
| - Price on application |
| SOL-X SOLID STATE DETECTOR FOR D8 | Location: Karlsruhe |
| The Sol-X solid state detector is a energy dispersive X-ray detector suitable for X-ray diffraction experiments using energies between 2 keV and 30 keV. The Lithium drifted Silicon detector (Si(Li)) chip is cooled down to about -80°C by Peltier elements. The chip is mounted in a small vacuum reception having a Be entrance window for the incoming X-rays. The detector is mounted equivalent to a scintillation counter. The obtained count rate is transferred to the measurement electronics of the diffraction system. | |
| Remark: | |
| - ex Works Karlsruhe | |
| - Warranty 6 months | |
| - For more information and prices, please contact the above mentioned service persons. | |
| - Price on application |
| COBRA LOW TEMPERATURE DEVICE WITH DEDICATED NITROGEN GAS GENERATOR, 50HZ/230V | Location: Karlsruhe |
| It uses nitrogen gas, provided by an included Nitrogen gas generator, to produce a constant cold stream of nitrogen, down to a temperature of 80K. | |
| The nitrogen gas is cooled by the Cobra refrigerator (Gifford McMahon principle), and delivered to the Cobra head via a vacuum insulated transfer line. The Cryodrive and refrigerator can be kept outside the X-ray enclosure. | |
| An external stream of nitrogen gas at room temperature creates a shielding laminar flow, which prevents icing on the sample. | |
| Specifications: | |
| - Temperature range 80-400 K | |
| - Nitrogen gas flow rate 5 or 10 l/minute | |
| - Temperature stability 0.1 K | |
| - Cool down time to 100 K in 30 minutes | |
| - Coldhead weight 1.5 g | |
| - Length of transfer line (to end of nozzle) 2000 mm | |
| The Cobra consists of: | |
| - Cobra gas delivery head*, Cryostream style nozzle | |
| - 2 m flexible vacuum hose connecting head & refrigerator* | |
| - Cobra refrigerator incorporating a single stage GM coldhead* | |
| *The first 3 items can not be physically separated | |
| - Programmable temperature controller | |
| - Water-cooled GM refrigerator compressor (Cooling unit is not included) | |
| - Varibeam support stand | |
| - Nitrogen gas generator | |
| - For more information and prices, please contact the above mentioned service persons. | |
| - Price on application |
| VIDEO ZOOM MICROSCOPE FOR D8, 214 MM | Location: Karlsruhe |
| Color CCD video camera plus optical lens. Mounts to the base of SMART and PROTEUM/D8 Systems. | |
| Remark: | |
| - Price without installation | |
| - ex Works Karlsruhe | |
| - Delivery: on stock | |
| - Warranty 6 month | |
| - For more information and prices, please contact the above mentioned service persons. | |
| - Price on application |
| KRYO-FLEX LOW TEMPERATURE EQUIPMENT | Location: Karlsruhe |
| Age: about 1 1/2 years | |
| Low-consumption and highly stable Low-Temperature device based on a heat-exchanger principle. | |
| - Temperature range of < 90 K to 300 K | |
| - Stability of +/- 0.1 K | |
| - Nitrogen consumption < 0.5 l/hr | |
| - Electronic, user controlled gas-flow rate | |
| - 3000 mm flexible transfer line; will pass through D8 labyrinth | |
| - Extremely quiet pump as 19.-rack unit | |
| - Control electronics as 19.- rack unit | |
| - Safety features to check for Nitrogen gas flow present and | |
| - 60 l dewar included for 5 days autonomous operation | |
| - Automatic refill from optional supply dewar | |
| - Software control | |
| - Verification of the temperature in close vicinity of the | |
| - Nozzle with secondary dry air stream to avoid icing | |
| Remark: | |
| - Price without installation | |
| - ex Works Karlsruhe | |
| - Delivery: on stock | |
| - Warranty 6 month | |
| - For more information and prices, please contact the above mentioned service persons. | |
| - Price on application |